EXAMPLE 5.1. ESTIMATING HARDWARE

A wall partition  16.00 meters long by 3.00 meters high specify the use of 1" x 8" stone cut wood board on studs spaced at 0.60m o.c. Determine the nails required for the studs and the wood board.



A. Nails for studs:

                 

    From the table:



MATERIALSUNIT PERWEIGHT REQDSIZEKINDS OF NAILS
kg
Floor joist and bridging at 30 o.c.sq.m.0.1720dCWN
T & G flooring
1 x 4sq.m.0.156dFlooring brad
1 x 6sq.m.0.096dFlooring brad
Siding wood board on studs at 60 o.c.
1 x 6sq.m.0.086dCasing brad
1 x 8sq.m.0.066dCasing brad
Sutds
at 0.40 o.c.sq.m.0.088dCWN
at 0.60 o.c.sq.m.0.058dCWN
Saffoldingmeter ht of post0.7320dCWN
Plywood wall and ceilingPer sheet at 0.15 o.c. on 40 x 60 joist0.0552dFinishing nails
Rafters, Purlins and CleatsPer sq.m. purlins at 70 o.c.0.220dCWN
Base BoardMeter length0.036dCWN
Fascia BoardMeter length0.0488dCWN
Ceiling Joist at 40 x 60 o.c.sq.m.0.058dCWN

With stud at 0.60m on centers:





B. Nails for 1" x 8" Wood Board

Using 1 x 8 wood board: